MIL-C-17 RG Coaxial cable
Applications:
For use in communication and signal control systems.

Features
This coaxial cable conforms to MIL-C-17 specification
Order information
Option 1
| Construction details | |
| Inner conductor | 7/0.102mm SCCS or SC |
| Insulation | Solid FEP φ0.86±0.05mm |
| Outer conductor (braid) | Carrier:16 Ends:3 Wire:0.10mm or 0.12mm SC Coverage:93%(nom.) |
| Jacket | FEP OD:1.90mm |
| Engineering data | |
| Impedance | 50±3Ω (see diagram) |
| Capacitance | 95.5PF/M(nom.) |
| Velocity of propagation | 69% |
| Corona extinction Voltage | 1.0KV RMS |
| Dielectric strength | 2.0KV RMS |
| Insulation resistance | 5000MΩ (min.) |
| Attenuation at 400MHz | 950dB/KM (max.) (see diagram) |
Option 2| Construction details | |
| Inner conductor | 7/0.102mm SCCS or SC |
| Insulation | Solid FEP φ1.60 ± 0.07mm |
| Outer conductor (braid) | Carrier:16 Ends: 5 or 4 Wire:0.l 0mm or 0.12mm SC Coverage:93%(nom.) |
| Jacket | FEP OD:2.54 ± 0.12mm(max.) |
| Engineering data | |
| Impedance | 75±3Ω (see diagram) |
| Capacitance | 63.8PF/M(nom.) |
| Velocity of propagation | 69% |
| Corona extinction Voltage | 1.2KV RMS |
| Dielectric strength | 1.8KV RMS |
| Insulation resistance | 5000MΩ(min.) |
| Attenuation at 400MHz | 950dB/KM (max.) (see diagram) |
Option 3
| Construction details | |
| Inner conductor | 7/0.170mm SCCS or SC |
| Insulation | Solid FEP φ1.52 ± 0.07mm |
| Outer conductor (braid) | Carrier:16 Ends: 5 or 4 Wire:0.10mm or 0.12mm SC Coverage:95%(nom.) |
| Jacket | FEP OD:2.60mm |
| Engineering data | |
| Impedance | 50±30 (see diagram) |
| Capacitance | 95.5PF/M(nom.) |
| Velocity of propagation | 69% |
| Corona extinction Voltage | 1.2KV RMS |
| Dielectric strength | 2.0KV RMS |
| Insulation resistance | 5000MΩ (min.) |
| Attenuation at 400MHz | 688dB/KM (max.) (see diagram) |
.
share to
Share on facebook
Facebook
Share on google
Google+
Share on twitter
Twitter
Share on linkedin
LinkedIn
Share on whatsapp
WhatsApp
Share on email
Email