Wire gauge size chart | AWG table

Wire Gauge Size Chart

American wire gauge (AWG) size calculator and chart.

Wire gauge calculator

Select gauge #:  
Or enter gauge #: AWG
Select wire type:  
Resistivity: Ω·m
 
Diameter in inches: in
Diameter in millimeters: mm
Cross sectional area in kilo circular mils: kcmil
Cross sectional area in square inches: in2
Cross sectional area in square millimeters: mm2
Resistance per 1000 feet*: Ω/kft
Resistance per 1000 meters*: Ω/km

* @ 68°F or 20°C

** Results may change with real wires: different resistivity of material and number of strands in wire

AWG chart

AWG # Diameter
(inch)
Diameter
(mm)
Area
(kcmil)
Area
(mm2)
0000 (4/0) 0.4600 11.6840 211.6000 107.2193
000 (3/0) 0.4096 10.4049 167.8064 85.0288
00 (2/0) 0.3648 9.2658 133.0765 67.4309
0 (1/0) 0.3249 8.2515 105.5345 53.4751
1 0.2893 7.3481 83.6927 42.4077
2 0.2576 6.5437 66.3713 33.6308
3 0.2294 5.8273 52.6348 26.6705
4 0.2043 5.1894 41.7413 21.1506
5 0.1819 4.6213 33.1024 16.7732
6 0.1620 4.1154 26.2514 13.3018
7 0.1443 3.6649 20.8183 10.5488
8 0.1285 3.2636 16.5097 8.3656
9 0.1144 2.9064 13.0927 6.6342
10 0.1019 2.5882 10.3830 5.2612
11 0.0907 2.3048 8.2341 4.1723
12 0.0808 2.0525 6.5299 3.3088
13 0.0720 1.8278 5.1785 2.6240
14 0.0641 1.6277 4.1067 2.0809
15 0.0571 1.4495 3.2568 1.6502
16 0.0508 1.2908 2.5827 1.3087
17 0.0453 1.1495 2.0482 1.0378
18 0.0403 1.0237 1.6243 0.8230
19 0.0359 0.9116 1.2881 0.6527
20 0.0320 0.8118 1.0215 0.5176
21 0.0285 0.7229 0.8101 0.4105
22 0.0253 0.6438 0.6424 0.3255
23 0.0226 0.5733 0.5095 0.2582
24 0.0201 0.5106 0.4040 0.2047
25 0.0179 0.4547 0.3204 0.1624
26 0.0159 0.4049 0.2541 0.1288
27 0.0142 0.3606 0.2015 0.1021
28 0.0126 0.3211 0.1598 0.0810
29 0.0113 0.2859 0.1267 0.0642
30 0.0100 0.2546 0.1005 0.0509
31 0.0089 0.2268 0.0797 0.0404
32 0.0080 0.2019 0.0632 0.0320
33 0.0071 0.1798 0.0501 0.0254
34 0.0063 0.1601 0.0398 0.0201
35 0.0056 0.1426 0.0315 0.0160
36 0.0050 0.1270 0.0250 0.0127
37 0.0045 0.1131 0.0198 0.0100
38 0.0040 0.1007 0.0157 0.0080
39 0.0035 0.0897 0.0125 0.0063
40 0.0031 0.0799 0.0099 0.0050

Wire gauge calculations

Wire diameter calculations

The n gauge wire diameter dn in inches (in) is equal to 0.005in times 92 raised to the power of 36 minus gauge number n, divided by 39:

dn (in) = 0.005 in × 92(36-n)/39

The n gauge wire diameter dn in millimeters (mm) is equal to 0.127mm times 92 raised to the power of 36 minus gauge number n, divided by 39:

dn (mm) = 0.127 mm × 92(36-n)/39

Wire cross sectional area calculations

The n gauge wire's cross sercional area An in kilo-circular mils (kcmil) is equal to 1000 times the square wire diameter d in inches (in):

An (kcmil) = 1000×dn2 = 0.025 in2 × 92(36-n)/19.5

The n gauge wire's cross sercional area An in square inches (in2) is equal to pi divided by 4 times the square wire diameter d in inches (in):

An (in2) = (π/4)×dn2 = 0.000019635 in2 × 92(36-n)/19.5

The n gauge wire's cross sercional area An in square millimeters (mm2) is equal to pi divided by 4 times the square wire diameter d in millimeters (mm):

An (mm2) = (π/4)×dn2 = 0.012668 mm2 × 92(36-n)/19.5

Wire resistance calculations

The n gauge wire resistance R in ohms per kilofeet (Ω/kft) is equal to 0.3048×1000000000 times the wire's resistivity ρ in ohm-meters (Ω·m) divided by 25.42 times the cross sectional area An in square inches (in2):

Rn (Ω/kft) = 0.3048 × 109 × ρ(Ω·m) / (25.42 × An (in2))

The n gauge wire resistance R in ohms per kilometer (Ω/km) is equal to 1000000000 times the wire's resistivity ρ in ohm-meters (Ω·m) divided by the cross sectional area An in square millimeters (mm2):

Rn (Ω/km) = 109 × ρ(Ω·m) / An (mm2)